ETO Pureto Elica

Product Code.             : VM-PU-01


Features


  • Low temperature sterilization with a low sterilizing cost, space saving and user-friendly features
  • Designed to be used with Ethylene oxide gas cartridge for sterilization process at hospitals, research centers, laboratories and pharmaceutical applications.
  • EO gas is highly effective, have ability to penetrate the complex medical devices (such as an endoscopes)
  • Automatic door locking: Software controlled dexterous door locking system allows operator to release door using touch screen panel only when it is safe to do so.
  • No need of compressor: Compressor not required to avoid any other tedious maintenance and because unhealthy compressed air may damage performance of equipment.
  • Oil free system: Special vacuum system without any moving parts, so consistence in performance without any maintenance unlike other manufacturer.
  • Internal shell and outer body is made up of SS304
  • Door is made up of High Grade Aluminium
  • Heaters on all sides of chamber for uniform heating throughout the load
  • In-built humidity generator
  • Unit comes with an integrated printer
  • The entire sterilization cycle operates under vacuum for added safety and control.
  • Warm cycle: 55 degree approx for 7-8 hours and Cold cycle: 38 degree celcius for approx 7-8 hours.
  • Chamber safety valve and heat resistant silicon Gasket provided.
  • Chamber tested hydraulically at 3 BAR.
  • Chamber and door fabricated out of SS 316/304 grade steel.
  • Power supply is 220 V AC/50Hz.
  • ETO cartridge will be punctured automatically inside the chamber.
  • Digital data back-up facility – OPTIONAL
  • Audio alarm & visual display error messages on screen
  • Vibration less, noise less& Oil less Vacuum pump, Special vacuum system without any moving parts, so consistence in performance without any maintenance unlike other manufacturer.
  • Supervisory access codes and password protection for prevention of unauthorized access.
  • Temperature uniformly and accurately maintained throughout the chamber to within ± 1°C of the set sterilization temperature.
  • Safety:
  • Whole cycle run in vacuum to make sure that EO gas never expose to operator
  • Vacuum leakage checking before EO exposure
  • PLC system makes sure that EO cartridge has punctured.
  • Long vacuum delay alarm
  • High temperature alarm and provided with thermal switch.
  • Vibration less and heat less vacuum system for which is safe for EO gas
  • Automation
  • Control and Printing: Fully Automatic PLC control system provides on-line documentation through in-built printer (Optional).
  • Automation Hardware: PLC (CE approved, CLASS 1 DIV2 Groups ABCD Surrounding Temp 50°C)HMI 4.3” Colour touch screen
  • SCADA:Provides the option to link PC to the autoclave for remote control and monitoring. Records in three formats (Detailed Report, /Summary, Graph) can be stored in the PC and reprinted as and when required.